Home ProductsSafety Testing System

High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment

Certification
China Qingdao AIP Intelligent Instrument Co., Ltd certification
China Qingdao AIP Intelligent Instrument Co., Ltd certification
Customer Reviews
Reliable factory and product. 24h online service conduct us to solve the installation problem.

—— Carmen

Perfect product and service, thank for the professional recommendation, Safety testing system AIP9646 suits us very well.

—— Jasmine

AIP instrument is your ideal choice. High quality products,timely delivey , professional after sale service.

—— Nguyen Thanh Truyen

I'm Online Chat Now

High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment

High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment
High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment

Large Image :  High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment

Product Details:
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 45 work days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month

High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment

Description
Product Category: Safety Testing System OS: Windows XP
Data: Testing Data Can Be Exported In Excel Form Power Supply: Customized As The National Grid
Color: Grey (customized) Service: Support Remote Control Failure Diagnose
High Light:

electrical safety test equipment

,

laboratory testing equipment

Safety Testing System / The Cooker

 

1. Test item: power, leakage, insulation resistance, grounding, Hipot

 

2. The tested product reference picture

High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment 0

 

3. Technical specification

Test item

AC Hipot, Insulation resistance, Grounding resistance, leakage, power

Power

Output voltage

1.0 times rated voltage

Output voltage testing range / precision

AC 50~280V ±(0.5%×display value+2words)

Output current testing range / precision

AC 0.20~30.00A ±(0.5%×display value+2words)

Active power testing range / precision

30~6000W ±(0.5%×display value+5words)

Multi-position setting

4 positions can be set, identify position switch automatically, each position can display corresponding test data after complete the test.

Power setting alarm range

Max:3~6000W Min:0~6000W

Test time range / resolution

1~300s 1s/step

Insulation resistance

Output voltage setting range/ precision

DC 500/1000V ±(3%×reading +5 words)

Insulation resistance testing range / precision

1~2000MΩ ≤100MΩ:±(5%×display value +3 words) >100 MΩ:±(8%×display value +8words)

Insulation resistance alarm setting range

Max:0~2000MΩ;Min:1~2000MΩ

Test time range/ resolution

1~300s 1s/step

AC Hipot

Output voltage setting range/ precision

AC 200~5000V ±(3%×setting value+5 words)

Breakdown current testing range/ precision

0.10~25.00mA ±(3%×display value+5 words)

Breakdown current presetting alarm range

Max:0.10~25.00mA ;Min:0.00~5.00mA

Test time range/ resolution

1~300s 1s/step

Grounding resistance

Grounding current output range/ precision

AC 5.0~30.0A ±(3%×setting value +5 words)

Grounding resistance testing range/ precision

10.0~600mΩ ±(3%×display value+5 words)

Grounding resistance alarm setting range

Max:5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;

Min:0.0~100mΩ

Test time range/ resolution

1~60s 1s/step

Leakage

Output voltage

1.06 times rated voltage

Leakage type setting

Dynamic leakage, static leakage, optional equipped with 3 types of body network, which can be customized and switched freely.

Output voltage testing range / precision

AC 50~280V ±(0.5%×display value+2words)

Leakage current test range/ precision

0.05~20.00mA ±(1.5%×display value +0.02mA)

Leakage current setting alarm range

Max:0.05~20.00mA;Min:0.01~5.00mA

Test time range

1~300s 1s/step

 

4. Feature

  • Meet requirements in CCC, IEC, EN, VDE, BS, GS, UL and other general electrical safety specifications.
  • With 15 groups test conditions in memory and 8 testing steps are in each group, each set’s specification model can be set individually for quick search.
  • Fast: Tester control core takes ARM high-speed processor, which processes data in a quick and comprehensive way. Standard items tests can be done in 8 seconds.
  • Hi-pot voltage is featured with ramp up/down setting, max./min. alarm.
  • Optional voltage and resistance model for grounding resistance test, which meet different national or industry standard requirements.

 

5. Reference picture

High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment 1

 

6. Test accessory

High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment 2High Accuracy Safety Testing System , Grey Color AC Hipot Test Equipment 3

 

Contact Details
Qingdao AIP Intelligent Instrument Co., Ltd

Contact Person: Fiona Liu

Tel: +8613969776659

Send your inquiry directly to us (0 / 3000)