Grey Color Electrical Safety Test Equipment For Electric Water Heater

Product Details

Place of Origin: China

Brand Name: AIP

Model Number: AIP89XX

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: negotiation

Packaging Details: wooden case

Delivery Time: 45 work days

Payment Terms: L/C, T/T

Supply Ability: 50 sets per month

Get Best Price
High Light:

electrical safety test equipment

,

laboratory testing equipment

Power Supply:
Customized As The National Grid
Color:
Grey (customized)
Warranty:
12 Months
MES Connection:
Yes
Service:
Support Remote Control Failure Diagnose
Monitor:
5.7” LCD
Power Supply:
Customized As The National Grid
Color:
Grey (customized)
Warranty:
12 Months
MES Connection:
Yes
Service:
Support Remote Control Failure Diagnose
Monitor:
5.7” LCD
Grey Color Electrical Safety Test Equipment For Electric Water Heater

Safety Testing System / Electrical Safety Testing System for Electric Water Heater

 

1. Features: six test items can be finished in sequence at one time, AC Hipot, insulation resistance, grounding, low voltage start and power, the test order can be set as per your requirement. Reduce labor work, save testing space and improve production efficiency.

 

2. Tested object: home appliances / electric water heater

 

3. Technical parameters:

AC Hipot

Output voltage setting range/precision

AC 200~5000V ±(3%*setting value + 5 digit)

Breakdown current measuring range/precision

0.10~99.99mA ±(3%*displayed value + 5 digit)

Presetting breakdown current alarm range/precision

Up limit: 0.10~99.99mA;

Lower limit: 0.00~5.00mA

Testing time range/resolution

1~300S 1s/step

Insulation resistance

Output voltage setting range/precision

DC 500/1000V ±(3%*displayed value + 5 digit)

Insulation resistance measuring range/precision

1~2000MΩ Within 100MΩ:±(5%*displayed value + 3 digit);

Above 100MΩ:±(8%*displayed value + 8 digit);

Presetting insulation resistance alarm range/precision

Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ

Testing time range/resolution

1-300s 1s/step

Grounding

Ground current output range/precision

AC 5.0~30.0A ±(3%*setting value + 5 digit)

Ground resistance measuring range/precision

10.0~600mΩ±(3%*displayed value + 5 digit)

Presetting ground resistance alarm range

Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ

Lower limit: 0.0 ~100mΩ

Testing time/resolution

1~60s 1s/step

Leakage current

Output voltage

1.06 times of nominal voltage

Output voltage measuring range/precision

AC 50~280V ±(0.5%*displayed value + 2 digit)

Leakage current measuring range/precision

0.05~20.00mA ±(3%*displayed value +0.02mA)

Presetting leakage current alarm range

Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA

Testing time range/resolution

1~300s 1s/step

power

Output voltage

Equals input voltage

Output voltage measuring range/precision

AC 50~280V ±(0.5%*displayed value + 2 digit)

Output current measuring range/precision

AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

Power measuring range/precision

30~6000W ±(0.5%*displayed value + 5 digit)

Presetting power alarm range

Up limit: 30~6000W; Lower limit: 0~6000W

Testing time/resolution

1~300s 1s/step

Low voltage starts

Output voltage

O.85 times of input voltage

Output voltage measuring range/precision

AC 50~280V ±(0.5%*displayed value + 2 digit)

Starting current measuring range/precision

AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

Presetting current alarm range

Up limit: 0.20~30.00A; Lower limit: 0.00~25.00A

Testing time/resolution

1~300s 1s/step

 

4. Main characteristics:

  • Meet the common electrical safety testing standards and requirements of CCC, ICE, EN, VDE, BS, GS, UL.
  • Optionally equipped with industrial computer, and to accomplish automatic control and data recording by using a barcode scanner device, and to build a platform of managing production data, and to communicate with the production management system.
  • Optionally equipped with the inverter to achieve automatic test, and the output voltage will be changed automatically. It has no effect on output results.
  • Storage space of test items and results is unlimited, maximum 8 test procedures for each testing group, each test group can be established with a type name. Type querying is available.
  • Test results can be exported via USB flash.

 

5. Image of tested objects for reference

Grey Color Electrical Safety Test Equipment For Electric Water Heater 0