Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89**
Payment & Shipping Terms
Minimum Order Quantity: 1 Set
Price: Negotiation
Packaging Details: Wooden case
Delivery Time: 45 working days
Supply Ability: 300 sets per month
Size: |
1405mm*660*840 |
Weight: |
140KG |
Language: |
Multiple |
Test Bench: |
Enclosed |
Temperature Compensation: |
Yes |
Display: |
10.4 Touch Screen |
Size: |
1405mm*660*840 |
Weight: |
140KG |
Language: |
Multiple |
Test Bench: |
Enclosed |
Temperature Compensation: |
Yes |
Display: |
10.4 Touch Screen |
Washing Machine Stator Testing System For Home Appliance Industry
1. Test object:
Stator of washing machine motor
2. Test items:
Insulation resistance, surge, winding resistance, AC Hipot, rotation
3. Function description:
3.1 Built in industrial computer (IPC), Linux operating system, professional control software
3.2 Indicating light: red, green and yellow
3.3 The resistance can be corrected to that under normal temperature when testing the DC winding
resistance.
3.4 The left station and right station works alternatively.
3.5 All items can be selected by the operator
3.6 ≥1000 motor models can be established.
3.7 The parameters range for each type of motor can be entered and saved. The inductance and
resistance test has the function of setting and displaying the unbalanced degree.
3.8 “Continue to test” and “stop the test” can be selected if the stator fails the test. If the stator fails the
winding resistance test, the test will be stopped until testing all the three windings.
3.9 The testing data can be exported via USB interface, including the test parameters.
3.10 The testing data can be exported via USB interface.
4. Test bench
5. Technical specification
Test Item | AC Hipot, insulation resistance, surge, winding resistance, and rotation | |
Test station | Dual station, standard equipped with test bench | |
Display | Keyboard + touch screen(10.4 ’) | |
AC Hipot | ||
Output voltage setting range/ precision | AC 500~3000V ±(2%×setting value+10V) | |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×display value+0.05mA) | |
Hipot breakdown current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA | |
Hipot current/resolution | ±(2%×display value+0.05 mA);0.01 mA | |
test time range/resolution | 0.5~999.9s 0.1s/step | |
Insulation resistance | ||
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) | |
insulation resistance testing range/precision | 1~500MΩ ≤100MΩ:±(3%×display value+0.5MΩ); >100MΩ:±(5%×display value+5MΩ) | |
insulation resistance alarm setting range | Max:0~500MΩ;Min:1~500MΩ | |
test time range/resolution | 0.5~999.9s 0.1s/step | |
Surge | ||
output voltage setting range/precision | 500~3000V ±(3%×display value+8V) | |
sampling frequency | 100MHz | |
Surge graph comparison | Area, area difference, corona, phase. Three surge graphs will be displayed on the test interface | |
DC winding resistance | ||
measuring range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set | |
test time range/resolution | 0.5~999s 0.1s/step | |
temperature compensation | Yes | |
temperature probe/measuring range | DS18b20 -10.0℃~+50.0℃ | |
test precision | ±0.5℃(range:-10℃~+50℃) | |
Direction of rotation | ||
rotation | CW/CCW/still |
6. Configuration list
No. | Name | Function | Unit | Quantity |
1 | Master unit | Control the test module and switch the test items, save testing data | Set | 1 |
2 | Test software | Save the test conditions/results, switch the test process | Set | 1 |
3 | Channel switch unit | Switch the let/right station | Set | 1 |
4 | Cabinet and power supply | Integrated driving module | Set | 1 |
5 | Test bench | Integrated customized test bench | Set | 1 |