Brushless DC Motor Testing Equipment With Driver Inside The BLDC Motor
1. Requirement analysis
1.1 Application: BLDC motor of air conditioner fan, exhaust fan, air purifier of home appliance industry
2. Test item and specification
2.1 Station: dual station
2.2 Clamping mode: the test bench is designed with wire connection terminal to connect the motor directly
2.3 Test items:
AC Hipot, insulation resistance, loading, RPM, rotation, FG/Hall
3. System introduction
Composed of test bench, IPC, master unit, system control software, and function modules, the system
could test safety performance, parameters and back EMF. Press the start button, all the items will be
tested in sequence, and display PASS or Fail.
With IPC, Windows system, professional software, clean interface, the testing system can be operated
easily and simplified the operating process. Standard equipped with three-color alarm light, pass or fail
can be seen through the red and green alarm light sign.
4. Technical parameters
AC Hipot | |
Output voltage setting range/precision | AC 200~3000V ±(3%×setting value+5 words) |
Breakdown current measuring range/precision | 0.10~25.00mA ±(3%×display value+5 words) |
Breakdown current presetting alarm range | Max:0.10~25.00mA;Min:0.00~5.00mA |
Test time range/resolution | 1~300s 1s/step |
Arc detection | 1~9 level(level 9 is the most sensitive) |
Insulation resistance | |
Output voltage setting range and precision | DC 500V/1000V ±(3%×setting value+3V) |
Insulation resistance measuring range and precison | 1~500MΩ ≤100MΩ:±(5%×display value+3 words) >100MΩ:±(8%×display value+8 words) |
Insulation resistance setting range/precision | Max:0~500MΩ;Min:1~500MΩ |
Test time range/resolution | 1~300s 1s/step |
On-load | |
Voltage measuring range/precision | Vm:DC 20.0~350.0V ±(0.5%×display value+1 word) |
Current measuring range/precision | Im:0.010~2.000A ±(0.5%×display value+2 words) |
Power measuring range | 10.0~700.0W |
RPM measuring range | Read the FG feedback signal, and calculate as to the output signal(within 3000rpm) |
On-load setting range | 0.20~0.75Nm |
Rotation | CW, CCW and still |
FG/Hall | |
High electric level range/precision | 3.0~18.0V ±(1%×display value+1 word) |
Low electric level range/precision | 0.0~18.0V ±(1%×display value+1 word) |
Frequency | 1 ~ 599Hz |
Duty cycle | 0.1-99.9% |
Others | |
Vsp power output range/precision | DC 1.00~18.00V ±(0.5%×setting value+1 word) |
Vcc power output range/precision | DC 1.00~18.00V ±(0.5%×setting value+1 word) |
Power sequence chart | Power on sequence:Vcc-Vm-Vsp,Power off sequence:Vsp-Vm-Vcc,both the time and sequence can be set. |
5. Test Process
5.1 Set the test sequence and parameters range as to the stator parameters and establish a new model
for this type of stator (The model of one stator type needs to be established only for the first time).
5.2 Put the tested stator on a designated station and clamp it.
5.3 Sliding cover to start the test and the “in-test” indication light is lightening.
5.4 All the items will be tested. The operator is not allowed to touch the stator during the test.
5.5 Pass or fail signal will be triggered after completing all items test.
5.6 Take out the tested stator and continue to test next one from step 2.