Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Wooden case
Delivery Time: 45 working days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Product: |
Motor Testing Machine For Air Conditioner Outdoor Unit Motor |
Application: |
Motor Factory Acceptance Test |
Test Station: |
Four Stations |
Port: |
USB, RS232, 485, CAN, Ethernet |
Software Upgrading: |
Support Remote Control |
MES Connection: |
Yes |
Product: |
Motor Testing Machine For Air Conditioner Outdoor Unit Motor |
Application: |
Motor Factory Acceptance Test |
Test Station: |
Four Stations |
Port: |
USB, RS232, 485, CAN, Ethernet |
Software Upgrading: |
Support Remote Control |
MES Connection: |
Yes |
Motor Testing Machine For Air Conditioner Outdoor Unit Motor / Motor Factory Test
I. Product introduction
1. Station: two stations
2. Integrated design make the testing machine can be moved easily. The test bench can be changed as different motor specification.
3. Both the touch screen and button can be used to operate the machine.
4. Standard equipped with self-diagnosis and remote control function, which makes the software upgrading and maintenance easier.
5. Motor reference pictures
II. Technical parameters:
2.1 AC Hipot:
Output voltage setting range and precision | AC 500~3000V ±(2%×setting value+10V) |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×setting value+0.05 mA) |
Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
Hipot current/resolution | ±(2% display value+0.05 mA);0.01 mA |
test time range/resolution | 0.5~999.9s 0.1s/step |
Arc detection | 0~9 level |
2.2 Surge:
output voltage setting range/precision | 500~3000V ±(3%×setting value+8V) |
sampling frequency | 100MHz |
waveform comparison | area, area difference, corona and phase 3 waveforms displayed in the testing interface |
2.3 Insulation Resistance:
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) |
insulation resistance testing range/precision |
1~500MΩ |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~100MΩ |
test time range/resolution | 0.5~999s 0.1s/step |
2.4 DC Winding resistance:
testing range and precision | 10.0mΩ~2KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
test time range/resolution |
0.5~20s 0.1s/step |
temperature compensation function | Yes |
temperature probe/range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
2.5 Low voltage start:
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
2.6 No-load:
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
2.7 Stall
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
2.8 Direction of rotation
rotation mode: Hall/MAC/inductance | |
rotation | CW, CCW, still |
III. Configuration list
No. | Name | Specification | Unit |
1 | Master unit | Customized | Set |
2 | Test bench | Customized clamps | Set |
3 | Cabinet unit | Easy to be moved with foot wheels | Set |
4 | Test software | Save the test requirements, data and control the test process | Set |