Send Message
Qingdao AIP Intelligent Instrument Co., Ltd
products
products
Home > products > Motor Testing Machine > Washing Machine Motor Quality Control Equipment Multiple Languages Available

Washing Machine Motor Quality Control Equipment Multiple Languages Available

Product Details

Place of Origin: China

Brand Name: AIP

Model Number: AIP89XX

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: Negotiable

Packaging Details: Wooden case

Delivery Time: 45 working days

Payment Terms: L/C, T/T

Supply Ability: 50 sets per month

Get Best Price
High Light:

electric motor testing panel

,

motor load test equipment

Product:
Washing Machine Motor Testing Machine
Application:
Washing Machine Motor Production Line
Test:
Hipot, IR, Surge, Resistance, Rotation, No-load, Power, Stall
Power Supply:
Customized
Station:
4 Stations
Warranty:
12 Months
Product:
Washing Machine Motor Testing Machine
Application:
Washing Machine Motor Production Line
Test:
Hipot, IR, Surge, Resistance, Rotation, No-load, Power, Stall
Power Supply:
Customized
Station:
4 Stations
Warranty:
12 Months
Washing Machine Motor Quality Control Equipment Multiple Languages Available

Washing Machine Motor Testing Machine, Quality Control Equipment For Production

 

1. Test product: washing machine motor

 

2. Application: washing machine industry

 

Washing Machine Motor Quality Control Equipment Multiple Languages Available 0

 

3. Product feature

High performance: compatible to test Hipot, insulation resistance, surge, winding resistance, rotation, no-load and stall.Easy-to-maintain: support intelligent self-diagnose, remote control failure diagnosis and online software upgrading.Modular design: independent test module design, all the test items are separatelyMultiple languages are available to meet the requirements of customers all around the world.Intelligent: the testing machine can connect to the Ethernet to achieve data interaction and resource share.

 

4. Technical parameters:

Insulation resistance
output voltage setting range/precision DC 500V/1000V ±(2%×setting value+10V)
insulation resistance testing range/precision

1~500MΩ

≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ)

insulation resistance alarm setting range Max: 0~500MΩ; Min: 1~500MΩ
test time range/resolution 0.5~999s 0.1s/step
AC Hipot
test time range/resolution 0.5~999.9s 0.1s/step
Output voltage setting range and precision AC 200~3000V ±(2%×setting value+10V)
breakdown current testing range/precision 0.10~20.00mA ±(2%×display value+0.05 mA)
Hipot current presetting alarm range Max:0.10~20.00mA;Min:0.00~20.00mA
Surge
output voltage setting range/precision 500~3000V ±(3%×display value+8V)
sampling frequency 100MHz
waveform comparison

area, area difference, corona and phase

3 waveforms displayed in the testing interface

DC winding resistance test
testing range and precision 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set.
test time range/resolution

0.5~999s 0.1s/step

 

temperature compensation function Yes
temperature probe/range DS18b20 -10.0℃~+50.0℃
precision ±0.5°C(range: -10℃~+50℃)
Low voltage start
voltage testing range and precision AC:30~500V ±(0.5%×display value+1 words)
current testing range and precision AC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision 0.6-1500W ±(0.5%×display value+5 words)
Stall
voltage testing range and precision AC:30~500V ±(0.5%×display value+1 word)
current testing range and precision AC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision 0.6-1500W ±(0.5%×display value+5 words)
No-load
voltage testing range and precision AC:30~500V ±(0.5%×display value+1 word)
current testing range and precision AC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision 0.6-1500W ±(0.5%×display value+5 words)
Direction of rotation
rotation CW, CCW, still

 

5. Test method

  • Set the test sequence and parameters range as to the stator parameters and establish a new model for this type of stator (The model of one stator type needs to be established only for the first time).
  • Put the tested stator on the test bench and clamp it.
  • Sliding cover to start the test and the “in-test” indication light is on.
  • All the items will be tested in sequence. The operator is not allowed to touch the stator during the test.
  • Pass or fail signal will be triggered after completing the test.
  • Take out the tested stator and continue to test next one from step 2.