Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: Negotiatiable
Packaging Details: Wooden case
Delivery Time: 45 working days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Product: |
Fan Motor Testing Machine |
Test: |
Hipot/ IR/ Surge/ Resistance/ No-load/ Power/ Stall |
Station: |
Two Stations |
Power Supply: |
Customized |
Alarm Light: |
Red, Yellow And Green |
Warranty: |
12 Months |
Product: |
Fan Motor Testing Machine |
Test: |
Hipot/ IR/ Surge/ Resistance/ No-load/ Power/ Stall |
Station: |
Two Stations |
Power Supply: |
Customized |
Alarm Light: |
Red, Yellow And Green |
Warranty: |
12 Months |
Fan Motor Testing Machine, Hipot/ IR/ Surge/ Resistance/ No-load/ Low voltage start/ Stall
1. Product specification and test item
1.1 Station: two stations
1.2 Clamping mode: test clamps, standard equipped with 8-digit clamps
1.3 Test object: fan motor
1.4 Tests: insulation resistance, winding resistance, rotation, low-voltage start, no-load, stall, Hipot and surge
1.5 Motor picture
2. System introduction
The fan motor testing machine adopts Linux operating system to control the software. It has both the stability of Linux system and friendly interface of Windows system, which can be used to perform the electrical parameters test for the motor of fan, air conditioner and vacuum cleaner, power tools etc.
3. Technical parameters:
3.1 Insulation Resistance:
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) |
insulation resistance testing range/precision |
1~500MΩ ≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ) |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~100MΩ |
test time range/resolution | 0.5~999s 0.1s/step |
3.2 DC Winding resistance:
testing range and precision | 10.0mΩ~2KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
test time range/resolution |
0.5~20s 0.1s/step
|
temperature compensation function | Yes |
temperature probe/range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
3.3 Direction of rotation
rotation mode: Hall/MAC/inductance | |
rotation | CW, CCW, still |
3.4 Low voltage start:
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
3.5 No-load:
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
3.6 Stall
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
3.7 AC Hipot:
Output voltage setting range and precision | AC 500~3000V ±(2%×setting value+10V) |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×setting value+0.05 mA) |
Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
Hipot current/resolution | ±(2% display value+0.05 mA);0.01 mA |
test time range/resolution | 0.5~999.9s 0.1s/step |
Arc detection | 0~9 level |
3.8 Surge:
output voltage setting range/precision | 500~3000V ±(3%×setting value+8V) |
sampling frequency | 100MHz |
waveform comparison | area, area difference, corona and phase 3 waveforms displayed in the testing interface |