Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Wooden case
Delivery Time: 45 working days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Product: |
Electrical Fan Motor Testing Machine For Factory Acceptance Test |
Test Station: |
Two Stations |
Operating System: |
Linux System |
Start Mode: |
Button, Cover Sliding, Network |
Port: |
USB, RS232, 485, CAN Ethernet |
Power Supply: |
Customized |
Product: |
Electrical Fan Motor Testing Machine For Factory Acceptance Test |
Test Station: |
Two Stations |
Operating System: |
Linux System |
Start Mode: |
Button, Cover Sliding, Network |
Port: |
USB, RS232, 485, CAN Ethernet |
Power Supply: |
Customized |
Electrical Fan Motor Testing Machine For Factory acceptance Test
1. Tested motor picture
2. Machine introduction
2.1 Linux operating system, professional software, clear interface
2.2 The power supply of the testing machine accepts customization as national power grid required.
2.3 Standard equipped with yellow, green and red indicating light. Yellow-in test, green-pass, red-fail.
2.4 Test the environment temperature in real time during the DC winding resistance test. And the resistance testing result will convert to the standard temperature value automatically.
2.5 The left station and right station continue to test alternatively.
2.6 The test item can be selected by the operator.
2.7 The light and sound alarm will be triggered in case of any equipment failure or the test result is failed.
3. Technical specifications
AC Hipot | |
test time range/resolution | 0.5~999.9s 0.1s/step |
Output voltage setting range and precision | AC 200~3000V ±(2%×setting value+10V) |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×display value+0.05 mA) |
Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
Surge | |
output voltage setting range/precision | 500~3000V ±(3%×display value+8V) |
sampling frequency | 100MHz |
waveform comparison |
area, area difference, corona and phase 3 waveforms displayed in the testing interface |
Direction of rotation | |
rotation | CW, CCW, still |
DC winding resistance test | |
testing range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
test time range/resolution |
0.5~999s 0.1s/step |
temperature compensation function | Yes |
temperature probe/range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
Low voltage start | |
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
Stall | |
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
No-load | |
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
Insulation resistance | |
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) |
insulation resistance testing range/precision |
1~500MΩ ≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ) |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~500MΩ |
test time range/resolution | 0.5~999s 0.1s/step |
4. Warranty
Self-diagnose: the testing system has the function of self-diagnose, which could diagnose itself automatically and position the failure module when switch-on the testing system.The service engineers will check the equipment status or failure via remote control in case of problem occurs.Modular design makes the equipment can be maintained easily.