Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Wooden case
Delivery Time: 45 working days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Product: |
Shaded Pole Motor Testing Machine |
Application: |
Motor Production Line |
Function: |
8 In 1 Tester |
Color: |
Primary Aluminum |
Weight: |
150KG |
Power Supply: |
Customized |
Product: |
Shaded Pole Motor Testing Machine |
Application: |
Motor Production Line |
Function: |
8 In 1 Tester |
Color: |
Primary Aluminum |
Weight: |
150KG |
Power Supply: |
Customized |
Shaded Pole Motor Testing Machine, High Precision Motor Testing System
1. Motor picture
2. Product features
3. Technical parameters
Insulation resistance | |
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) |
insulation resistance testing range/precision |
1~500MΩ |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~500MΩ |
test time range/resolution | 0.5~999s 0.1s/step |
AC Hipot | |
test time range/resolution | 0.5~999.9s 0.1s/step |
Output voltage setting range and precision | AC 200~3000V ±(2%×setting value+10V) |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×display value+0.05 mA) |
Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
Surge | |
output voltage setting range/precision | 500~3000V ±(3%×display value+8V) |
sampling frequency | 100MHz |
waveform comparison |
area, area difference, corona and phase 3 waveforms displayed in the testing interface |
DC winding resistance test | |
testing range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
test time range/resolution |
0.5~999s 0.1s/step |
temperature compensation function | Yes |
temperature probe/range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
No-load | |
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |