Send Message
Qingdao AIP Intelligent Instrument Co., Ltd
products
products
Home > products > Stator Vacuum Testing Machine > Windows XP Stator Vacuum Testing Machine , High Stability Surge Test Equipment

Windows XP Stator Vacuum Testing Machine , High Stability Surge Test Equipment

Product Details

Place of Origin: China

Brand Name: AIP

Model Number: AIP89XX

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: negotiation

Packaging Details: wooden case

Delivery Time: 45 work days

Payment Terms: L/C, T/T

Supply Ability: 50 sets per month

Get Best Price
High Light:

electric vehicle testing equipment

,

surge testing machine

OS:
Windows XP
Power Supply:
Customized As The National Grid
Port:
USB, LAN, CAN, RS232, RS485, Ethernet
Monitor:
19" LCD
Color:
Green(customized)
Warranty:
1 Year
OS:
Windows XP
Power Supply:
Customized As The National Grid
Port:
USB, LAN, CAN, RS232, RS485, Ethernet
Monitor:
19" LCD
Color:
Green(customized)
Warranty:
1 Year
Windows XP Stator Vacuum Testing Machine , High Stability Surge Test Equipment

​​Stator Vacuum Testing Machine Of Washing Machine

 

1. The purpose of testing stator under vacuum

  • The stator failure will be detected easily under negative pressure. The testing environment of the stator is quite close to complete vacuum. The lower the pressure is, the longer the arc will be caused under same voltage.​

 

2. Test and introduction

  • Features: unique vacuum negative pressure technology, and the vacuum degree can be set (0~-90KPa).
  • Test: surge, AC Hipot, rotation, DC winding resistance, insulation resistance.

3. Technical specification

  • Surge
working ambient comparatively vacuum
output voltage setting range / precision 500~5000V ±(3%×display value+8V)
waveform comparison

area, area difference, corona and phase

3 waveforms displayed in the testing interface

  • Insulation Resistance
output voltage setting range / precision DC 500V/1000V ±(2%×setting value+10V)
insulation resistance testing range / precision

1~500MΩ

≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ)

insulation resistance alarm setting range Max: 0~500MΩ; Min: 1~100MΩ
test time range / resolution 0.5~999s 0.1s/step
  • Direction of rotation
Rotation mode:
rotation CW, CCW, still
  • DC Winding resistance 
testing range and precision 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set.
test time range / resolution

0.5~999s 0.1s/step

 

temperature compensation function Yes
temperature probe / range DS18b20 -10.0℃~+50.0℃
precision ±0.5°C(range: -10℃~+50℃)
  • AC Hipot
Output voltage setting range and precision AC 500~5000V ±(2%×setting value+10V)
breakdown current testing range / precision 0.10~20.00mA ±(2%×display value+0.05 mA)
Hipot current presetting alarm range Max:0.10~20.00mA;Min:0.00~20.00mA
Hipot current / resolution ±(2% display value+0.05 mA);0.01 mA
test time range / resolution 0.5~999.9s 0.1s/step

 

4. Function description

  • Standard equipped with two stations. All the tests can be done at one-stop. The production efficiency will be highly improved.
  • Tests can be selected or unselected as required. The testing parameters can be set according to the requirements. The light and voice alarm will be triggered automatically if the tested parameters exceed the setting range.
  • Automatic voltage adjusting mode, output voltage of the Hipot and insulation resistance will be corrected automatically to ensure the test accuracy.
  • The winding quality won’t be affected by the surge test, which takes the testing mode of undamaged capacitor impulse discharge. Closed loop feedback control ensures the accuracy of the output impulse voltage.
  • Correct the resistance to that under standard temperature automatically when performing the DC winding resistance test. The consistency of the test result will be guaranteed.

 

5. Others

  • Built-in IPC, professional software, clean interface.
  • Yellow, green and red three-color indicating light.
  • All the tests can be selected or unselected.
  • Two options are available if NG appears: “continue to test” and “stop the test”. If NG appears when testing the winding resistance, the test can be stopped after testing the three windings.