Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden package
Delivery Time: 45 work days
Supply Ability: 50 sets per month
Monitor: |
19" LCD |
Port: |
USB, LAN, CAN, RS232, RS485, Ethernet |
Color: |
Green(customized) |
Power Supply: |
Customized As The National Grid |
Production Line Connection: |
Yes |
Station: |
2 Stations |
Monitor: |
19" LCD |
Port: |
USB, LAN, CAN, RS232, RS485, Ethernet |
Color: |
Green(customized) |
Power Supply: |
Customized As The National Grid |
Production Line Connection: |
Yes |
Station: |
2 Stations |
Stator Vacuum Testing Machine For Commercial Air Conditioner Compressor Motor
1. Stator Vacuum Testing Machine description
1.1 Test object: stator of commercial air conditioner compressor motor
1.2 Features: unique vacuum negative pressure technology, and the environment vacuum (0~-90KPa)can be set freely. It is easier to find the failure of coils in the negative pressure condition.
1.3 Function description:
2. Technical specification
Surge |
|
Test ambient |
Comparatively vacuum |
Output voltage setting range / precision |
500~3000V ±(3%×display value+8V) |
Waveforms comparison |
Aarea, area difference, corona, phase, 3 waveforms displayed in the testing interface |
AC Hipot |
|
Output voltage setting range / precision |
AC 200~3000V ±(2%×setting value+10V) |
Breakdown current testing range / precision |
0.10~20.00mA ±(2%×display value+0.05mA) |
Breakdown current presetting alarm range |
Max:0.10~20.00mA;Min:0.00~20.00mA |
Test time range / resolution |
0.5~999.9s 0.1s/step |
Rotation |
|
Direct of rotation |
CW, CCW, still |
DC winding resistance test |
|
Test range and precision |
10.0mΩ~20KΩ ±(0.3%×display value+3words) Temperature compensation can be set |
Test time range / resolution |
0.5~999s 0.1s/step |
Test range |
-10.0℃~+50.0℃ |
Test precision |
±0.5℃(range:-10℃~+50℃) |
Insulation resistance |
|
Output voltage setting range/ precision |
DC 500V/1000V ± (2%×setting value+10V) |
Insulation resistance testing range / precision |
1~500MΩ ≤100MΩ:±(3%×display value+0.5MΩ); >100MΩ:± (5%×display value+5MΩ) |
Insulation resistance alarm setting range |
Max:0~500MΩ;Min:1~500MΩ |
Test time range / resolution |
0.5~999.9s 0.1s/step |
3. After-sales service
3.1 Self-check: check the machine run smoothly or not, and locate the failure modular card automatically.
3.2 Check the fault via remote control
When the machine is in trouble, the after-sales service is not subject to distance restrictions.
3.3 Modular design makes the maintenance easier
Standard equipped modular, when the equipment is in trouble, rapid delivery to the site, can be replaced by the customer.
4. Stator vacuum testing Machine detail pictures