Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 45 work days
Supply Ability: 50 sets per month
MES Connection: |
Yes |
Service: |
24 Hour Quick Response |
Monitor: |
19” LCD |
Warranty: |
12 Months |
Data: |
Testing Data Can Be Exported In Excel Form |
OS: |
Windows XP |
MES Connection: |
Yes |
Service: |
24 Hour Quick Response |
Monitor: |
19” LCD |
Warranty: |
12 Months |
Data: |
Testing Data Can Be Exported In Excel Form |
OS: |
Windows XP |
Brushless Motor Tester For BLDC Motor Of Air Conditioner Indoor Unit
1. Application industry: BLDC motor of air conditioner indoor unit
2. Technical specification:
Insulation resistance |
|
Output voltage setting range/ precision |
DC 500V/1000V ± (3%×setting value+3V) |
Insulation resistance measuring range/ precision |
1~500MΩ ≤100MΩ:±(5%×display value+3words) >100MΩ:± (8%×display value+8words) |
Insulation resistance alarm setting range |
Max: 0~500MΩ;Min:1~500MΩ |
Measuring time range / resolution |
1~300s 1s/step |
Output voltage setting range/ precision |
DC 500V/1000V ± (3%×setting value+3V) |
On load |
|
Voltage test range/precision |
Vm:DC 20.0~350.0V ±(0.5%×display value+1word) |
Current test range/precision |
Im:0.010~2.000A ±(0.5%×display value+2words) |
Power measuring range |
0.20~0.75Nm |
RPM measuring range |
Read the FG feedback signal, and calculate as to the output signal(within 3000rpm) |
Rotation measuring |
CW, CCW, still |
AC Hipot |
|
Output voltage measuring range/ precision |
AC 200~3000V ±(3%×setting value+5words) |
Breakdown current measuring range/ precision |
0.10~25.00mA ±(3%×display value+5words) |
Breakdown current presetting alarm range |
Max: 0.10~25mA; Min: 0.00~5.00mA |
Measuring time range/ resolution |
1~300s 1s/step |
3. Test item and specification
3.1 Test object: air conditioner indoor unit
3.2 Clamping mode: the test bench is designed with wire connection terminal to connect the motor directly
3.3 Test item:
3.3.1 AC Hipot, insulation resistance;
3.3.2 On load: on load voltage, on load current, on load power, rotation, RFM
3.3.3 Station: single / dual
3.3.4 Introduction of tester: brushless motor tester mainly applies to test the comprehensive performance of motor for fan and air conditioner, which can meet the online testing of brushless motor
4. Configuration list
Optional: three- color alarm light
No. | Product | Function | Unit | Qty |
1 | Master unit | Testing module control, switch test items, data save | Set | 1 |
2 | Testing module | High voltage output, data acquisition | Set | 1 |
3 | Test software | Save test items and result, control the test process | Set | 1 |
4 | Channel switching unit | Right and left station switch/ winding switch | Set | 1 |
5 | Cabinet and equipment device | Drive module integrated and power cabinet, with casters easy to move | Set | 1 |
6 | Test bench | Customized integrated test bench | Set | 1 |
5. After-sale service
5.1 Remote diagnosis
The service engineers will check the equipment status or failure via remote control in case of problem occurs.
5.2 Modular design
Standard equipped modular board card, which can be delivered to customer site immediately and replaced by the customer when the board card has problem.
5.3 Self-diagnose
The tester has the function of self-diagnose, which could diagnose itself automatically and position the failure module when switch-on the testing system.
6. Brushless motor tester picture