Product Details:
|
Data Exportation: | Support USB Flash Drive Exportation | Warranty: | 12 Months |
---|---|---|---|
OS: | Windows XP | Color: | Grey (customized) |
Power Supply: | Customized As The National Grid | Monitor: | 5.7” LCD Blue Background |
High Light: | electrical safety analyzer,laboratory testing equipment |
Safety Testing System / Home Appliance / Laboratory
1. Test object: home appliance production line, laboratory
2. Test items: Hipot, grounding, leakage current, insulation resistance, power
3. Technical specification
AC Hipot |
|
Output voltage setting range/ precision |
AC 200~5000V ±(3%×setting value+5words) |
Breakdown current testing range/ precision |
0.10~25.00mA ±(3%×setting value+5words) |
Breakdown current presetting alarm range |
Max:0.10~25.00mA ;Min:0.00~5.00mA |
Test time range/ resolution |
1~300s 1s/step |
Grounding resistance |
|
Grounding current output range/ precision |
AC 5.0~30.0A ±(3%×setting value+5words) |
Grounding resistance alarm setting range |
Max:5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ; Min:0.0~100mΩ |
Grounding resistance test range/ precision |
10.0~600mΩ ±(3%×display value+5words) |
Test time/ resolution |
1~60s 1s/step |
Leakage current |
|
Output voltage |
1.06 times rated voltage (external provided) |
Leakage type setting |
Dynamic leakage, static leakage, optional equipped with 3 types of body network, which can be customized and switched freely. |
Output voltage setting range/precision |
AC 50~280V ±(0.5%×display value+2 words) |
Leakage current setting range/precision |
0.05~20.00mA ±(3%×display value+10uA) |
Leakage current setting alarm range |
Max.: 0.05~20.00mA; Min.: 0.01~5.00mA |
Test time range/resolution |
1~300s 1s/step |
Insulation resistance |
|
Output voltage setting range/ precision |
DC 500/1000V ±(3%×reading value+5 words) |
Insulation resistance testing range |
1~2000MΩ ≤100MΩ:±(5%×display value +3 words) >100 MΩ:±(8%×display value +8 words) |
Insulation resistance alarm setting range |
Max:0~2000MΩ;Min:1~2000MΩ |
Test time range/ resolution |
1~300s 1s/step |
Power |
|
Output voltage |
1.0 times rated voltage |
Output voltage measurement range/precision |
AC 50~280V ±(0.5%×display value+2 words) |
Output current measurement range/precision |
AC 0.20~30.00A ±(0.5%×display value+2 words) |
Active power measurement range/precision |
30~6000W ±(0.5%×display value+5 words) |
Power setting alarm range |
Max.: 3~6000W Min.: 0~6000W |
Test time range/resolution |
1~300s 1s/step |
4. Introduction