Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 45 work days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Data Exportation: |
Support USB Flash Drive Exportation |
Warranty: |
12 Months |
OS: |
Windows XP |
Color: |
Grey (customized) |
Power Supply: |
Customized As The National Grid |
Monitor: |
5.7” LCD Blue Background |
Data Exportation: |
Support USB Flash Drive Exportation |
Warranty: |
12 Months |
OS: |
Windows XP |
Color: |
Grey (customized) |
Power Supply: |
Customized As The National Grid |
Monitor: |
5.7” LCD Blue Background |
Safety Testing System / Desktop Type Safety Tester
1. Introduction
As a requested test by the international safety certification organization, Hipot must be performed to ensure the products electrical safety. The testing method is to apply the voltage higher than the normal working voltage to the product for a while, and check whether there is bad insulation condition.
Apply DC voltage (up to 1000 volt) to the concerned two terminals and check the insulation. Normally the unit of the tested resistance is Ohm.
Ground impedance test is to test the grounding terminal of the tested products. Apply a certain current to the product case or metal part and check the impedance of two terminals. Normally the impedance should be less than 0.1 ohm if the applied current is 25A. According to the requirement of CSA, the loose screw on ground terminal, ground lead small diameter and ground lead disconnection will be tested under 40A.
Leakage current test is the current that go through the touchable metal part and human body to the ground. It is the current of the touchable part on the product.
The purpose of power test is to test whether the input circuit can withstand the current required when the product is in normal operation. It is stipulated in the product standard that the input current of the maximum power consumption shall not be greater than 110% of the product's nominal value. This nominal value also tells the user the minimum current required for the product's safety work, and reminds the user to prepare such an electrical environment before using the device.
2. Features
The safety testing system supports to test both the safety and power, providing 2-channel test power input and solve the problem of power switch caused by the voltage inconsistency of leakage current test and power test. Optional equipped with the USB port for testing data save and export.
3. Technical parameter
Test item |
AC Hipot, DC Hipot, Insulation resistance, Grounding resistance, leakage, power |
Data save mode |
USB save |
AC Hipot |
|
Output voltage setting range/ precision |
AC 200~5000V ±(3%×setting value+5 words) |
Breakdown current testing range/ precision |
0.10~25.00mA ±(3%×display value+5 words) |
Breakdown current presetting alarm range |
Max:0.10~25.00mA ;Min:0.00~5.00mA |
Test time range/ resolution |
1~300s 1s/step |
Insulation resistance |
|
Output voltage setting range/ precision |
DC 500/1000V ±(3%×reading +5 words) |
Insulation resistance testing range / precision |
1~2000MΩ ≤100MΩ:±(5%×display value +3 words) >100 MΩ:±(8%×display value +8words) |
Insulation resistance alarm setting range |
Max:0~2000MΩ;Min:1~2000MΩ |
Test time range/ resolution |
1~300s 1s/step |
Grounding resistance |
|
Grounding current output range/ precision |
AC 5.0~30.0A ±(3%×setting value +5 words) |
Grounding resistance testing range/ precision |
10.0~600mΩ ±(3%×display value+5 words) |
Grounding resistance alarm setting range |
Max:5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ; Min:0.0~100mΩ |
Test time range/ resolution |
1~60s 1s/step |
Power |
|
Output voltage |
1.0 times rated voltage |
Output voltage testing range / precision |
AC 50~280V ±(0.5%×display value+2words) |
Output current testing range / precision |
AC 0.20~30.00A ±(0.5%×display value+2words) |
Active power testing range / precision |
30~6000W ±(0.5%×display value+5words) |
Multi-position setting |
4 positions can be set, identify position switch automatically, each position can display corresponding test data after complete the test. |
Power setting alarm range |
Max:3~6000W Min:0~6000W |
Test time range / resolution |
1~300s 1s/step |
Leakage |
|
Output voltage |
1.06 times rated voltage |
Leakage type setting |
Dynamic leakage, static leakage ,optional equipped with 3 types of body network ,,which can be customized and switched freely. |
Output voltage testing range / precision |
AC 50~280V ±(0.5%×display value+2words) |
Leakage current test range/ precision |
0.05~20.00mA ±(1.5%×display value +0.02mA) |
Leakage current setting alarm range |
Max:0.05~20.00mA;Min:0.01~5.00mA |
Test time range |
1~300s 1s/step |
4. Feature