Send Message
Qingdao AIP Intelligent Instrument Co., Ltd
products
products
Home > products > Safety Testing System > Intelligent Safety Testing System Easy Disassembly For Microwave Oven

Intelligent Safety Testing System Easy Disassembly For Microwave Oven

Product Details

Place of Origin: China

Brand Name: AIP

Model Number: AIP89XX

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: negotiation

Packaging Details: wooden case

Delivery Time: 45 work days

Payment Terms: L/C, T/T

Supply Ability: 50 sets per month

Get Best Price
High Light:

electrical safety test equipment

,

laboratory testing equipment

Product Category:
Safety Testing System
Warranty:
12 Months
OS:
Windows XP
Color:
Grey (customized)
Power Supply:
Customized As The National Grid
Monitor:
5.7” LCD Blue Background
Product Category:
Safety Testing System
Warranty:
12 Months
OS:
Windows XP
Color:
Grey (customized)
Power Supply:
Customized As The National Grid
Monitor:
5.7” LCD Blue Background
Intelligent Safety Testing System Easy Disassembly For Microwave Oven

Safety Testing System / Microwave Oven

 

1. Test object: microwave oven

 

2. Technical specification

Test items

AC Hipot, DC Hipot, Insulation resistance, Grounding resistance, leakage, power

Data save mode

USB save

Insulation resistance

Output voltage setting range/ precision

DC 500/1000V ±(3%×reading +5 words)

Insulation resistance testing range / precision

1~2000MΩ ≤100MΩ:±(5%×display value +3 words) >100 MΩ:±(8%×display value +8words)

Insulation resistance alarm setting range

Max:0~2000MΩ;Min:1~2000MΩ

Test time range/ resolution

1~300s 1s/step

AC Hipot

Output voltage setting range/ precision

AC 200~5000V ±(3%×setting value+5 words)

Breakdown current testing range/ precision

0.10~25.00mA ±(3%×display value+5 words)

Breakdown current presetting alarm range

Max:0.10~25.00mA ;Min:0.00~5.00mA

Test time range/ resolution

1~300s 1s/step

Leakage

Output voltage

1.06 times rated voltage

Leakage type setting

Dynamic leakage, static leakage, optional equipped with 3 types of body network, which can be customized and switched freely.

Output voltage testing range / precision

AC 50~280V ±(0.5%×display value+2words)

Leakage current test range/ precision

0.05~20.00mA ±(1.5%×display value +0.02mA)

Leakage current setting alarm range

Max:0.05~20.00mA;Min:0.01~5.00mA

Test time range

1~300s 1s/step

Power

Output voltage

1.0 times rated voltage

Output voltage testing range / precision

AC 50~280V ±(0.5%×display value+2words)

Output current testing range / precision

AC 0.20~30.00A ±(0.5%×display value+2words)

Active power testing range / precision

30~6000W ±(0.5%×display value+5words)

Multi-position setting

4 positions can be set, identify position switch automatically, each position can display corresponding test data after complete the test.

Power setting alarm range

Max:3~6000W Min:0~6000W

Test time range / resolution

1~300s 1s/step

Grounding resistance

Grounding current output range/ precision

AC 5.0~30.0A ±(3%×setting value +5 words)

Grounding resistance testing range/ precision

10.0~600mΩ ±(3%×display value+5 words)

Grounding resistance alarm setting range

Max:5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;

Min:0.0~100mΩ

Test time range/ resolution

1~60s 1s/step

 

3. Introduction

  • Four common tests are in safety test: insulation resistance, Hipot, leakage current, grounding resistance.
  • Hipot test include AC Hipot and DC Hipot test.
  • DC Hipot is similar with insulation resistance test except that the applied voltage is higher during the Hipot test, and the test result is displayed as leakage current. The insulated part of most tested products has distributed capacitor given that most tested products have big insulation resistor. During the DC Hipot test, actual leakage current flowing through the measured product when the scattered capacitor on the tested product is charged. Therefore, the DC Hipot can accurately test the actual leakage current.
  • Leakage current includes dynamic leakage current and static leakage current according to the tested equipment working status.
  • Static leakage current: Apply 1.06 times voltage to the tested product and measure the leakage current of the phase line and null line to case and ground when the tested product under the non-working state with the power switch on.
  • Dynamic leakage current (Leakage current at working temperature): The load shall be supplied through the isolated power supply (isolation transformer), which shall provide 1.15 times rated input power for the electric heating appliance and 1.06 times rated voltage for the electric appliance, respectively measuring the leakage current value of the phase line and null line to the case or ground.

 

​4. Features:

  • 5.7’ blue monitor, data display is clean.
  • Meet the electricity safety general standard requirements of CCC, IEC, EN, VDE, BS, GS, UL.
  • With 15 groups test conditions in memory, and 8 test steps in each group. Each group can set specification respectively, and search conveniently.
  • High speed: safety testing system equipped with ARM high speed processor, which process data comprehensively and fast.
  • Optional IPC achieve control and input data automatically with barcode scanner, the production data management platform can be connected to the production management system.
  • Optional inverter to adjust the output power supply automatically, ensure the test accuracy without human intervention.

Intelligent Safety Testing System Easy Disassembly For Microwave Oven 0