Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 45 work days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Power Supply: |
Customized As The National Grid |
Color: |
Grey (customized) |
Warranty: |
12 Months |
MES Connection: |
Yes |
Service: |
Support Remote Control Failure Diagnose |
Monitor: |
5.7” LCD |
Power Supply: |
Customized As The National Grid |
Color: |
Grey (customized) |
Warranty: |
12 Months |
MES Connection: |
Yes |
Service: |
Support Remote Control Failure Diagnose |
Monitor: |
5.7” LCD |
Safety Testing System / Electrical Safety Testing System for Home Appliances
1. Application industries: home appliances manufacturers, home appliances safety certificate authority, research center/institute
2. Main characteristic: six test items will be finished in sequence at one time, AC Hipot, insulation resistance, grounding, low voltage starts and power as per your setting order. Reduce labor work, save testing space and improve production efficiency.
3. Technical parameters:
AC Hipot |
|
Output voltage setting range/precision |
AC 200~5000V ±(3%*setting value + 5 digit) |
Breakdown current measuring range/precision |
0.10~99.99mA ±(3%*displayed value + 5 digit) |
Presetting breakdown current alarm range/precision |
Up limit: 0.10~99.99mA; |
Testing time range/resolution |
1~300S 1s/step |
Insulation resistance |
|
Output voltage setting range/precision |
DC 500/1000V ±(3%*displayed value + 5 digit) |
Insulation resistance measuring range/precision |
1~2000MΩ Within 100MΩ: ±(5%*displayed value + 3 digit); |
Presetting insulation resistance alarm range/precision |
Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ |
Testing time range/resolution |
1-300s 1s/step |
Grounding |
|
Ground current output range/precision |
AC 5.0~30.0A ±(3%*setting value + 5 digit) |
Ground resistance measuring range/precision |
10.0~600mΩ±(3%*displayed value + 5 digit) |
Presetting ground resistance alarm range |
Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ |
Testing time/resolution |
1~60s 1s/step |
Leakage current |
|
Output voltage |
1.06 times of nominal voltage |
Output voltage measuring range/precision |
AC 50~280V ±(0.5%*displayed value + 2 digit) |
Leakage current measuring range/precision |
0.05~20.00mA ±(3%*displayed value +0.02mA) |
Presetting leakage current alarm range |
Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA |
Testing time range/resolution |
1~300s 1s/step |
power |
|
Output voltage |
Equals input voltage |
Output voltage measuring range/precision |
AC 50~280V ±(0.5%*displayed value + 2 digit) |
Output current measuring range/precision |
AC 0.20~30.00A ±(0.5%*displayed value + 2 digit) |
Power measuring range/precision |
30~6000W ±(0.5%*displayed value + 5 digit) |
Presetting power alarm range |
Up limit: 30~6000W; Lower limit: 0~6000W |
Testing time/resolution |
1~300s 1s/step |
Low voltage starts |
|
Output voltage |
O.85 times of input voltage |
Output voltage measuring range/precision |
AC 50~280V ±(0.5%*displayed value + 2 digit) |
Starting current measuring range/precision |
AC 0.20~30.00A ±(0.5%*displayed value + 2 digit) |
Presetting current alarm range |
Up limit: 0.20~30.00A; Lower limit: 0.00~25.00A |
Testing time/resolution |
1~300s 1s/step |
4. About electrical safety testing: