Send Message
Qingdao AIP Intelligent Instrument Co., Ltd
products
products
Home > products > Rotor Testing Machine > Stepper Motor Stator Test System

Stepper Motor Stator Test System

Product Details

Place of Origin: China

Brand Name: AIP

Model Number: AIP89XX

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: negotiation

Packaging Details: wooden package

Delivery Time: 45 work days

Payment Terms: L/C, T/T

Supply Ability: 50 sets per month

Get Best Price
High Light:

Stepper Motor Stator Test System

,

19in LCD Stator Test System

,

Continuous Mode Rotor Testing Machine

Warranty:
12 Months
Data:
Testing Data Can Be Exported In Excel Form
Power Supply:
Customized As The National Grid
Color:
Customized
MES Connection:
Yes
OS:
Windows XP
Warranty:
12 Months
Data:
Testing Data Can Be Exported In Excel Form
Power Supply:
Customized As The National Grid
Color:
Customized
MES Connection:
Yes
OS:
Windows XP
Stepper Motor Stator Test System

Stepper motor stator test system

 

Motor stator test system
 
1.1 Equipment composition: dynamometer bench, dynamometer controller, DC power meter, torque speed power meter, measurement software, system integration control cabinet and all accessories required for the test (the purchaser only provides the site and power supply);
1.2 The main test parameters of the equipment: AC and DC voltage, AC and DC current, AC and DC power, torque, speed, output power, efficiency;
1.3 Test mode: with manual, automatic, fixed-point, durability, and temperature rise test modes.
1.4 Functional requirements: The load of the tested motor can be changed and tested at will, and the test characteristic curve can be drawn

2. Technical specification

 

Test object

Rotor of pump motor

Display mode

19” LCD

Test parameter

The quantity of bars, minimum amplitude, maximum amplitude, comprehensive value

Dimension range

Outer diameter 60-130mm

Inner diameter 10-50mm

Lamination thickness 180mm(max)

Test mode

Continuous mode: when test is over, the machine output the result, and the motor continue to work to acquire inductance waveforms until press the reset button, then stop the test.

Single mode: when test is over, the machine output the result and stop the test automatically at the same time.

Control mode

Auto/manual

Parameter save

Software save

Consumption

≤100w

Working ambient

Temperature 0~40℃, humility≤90%RH

 

System function introduction
 

1. Main performance:

 

(1) The test data are displayed digitally and can be sent to the computer for sampling, drawing and printing;

(2) Using high-precision load sensor; good stability, long service life, etc.;

(3) The whole machine has high sensitivity, load torque stability and test repeatability;

(4) Only adjusting the excitation current can control the size of the load

(5) The software operation is simple and easy to learn, and it can realize the test methods such as type experiment (manual, automatic), production line (fixed point, durable, fast experiment).

(6) The power tester has multiple ranges (automatic switching) to meet the test of high-power motors and low-power motors

(7) The three-dimensional adjustment table can easily install the motor and realize quick clamping. (for selection)

 

2. System function:

 

(1) The switch operation of the motor can be controlled on the computer;

(2) The system has manual and automatic test methods (this method can be operated without a computer). The entire process can be realized on the display controller on the control cabinet; the data can be locked for manual recording;

(3) The system has an automatic test method: the load is automatically loaded according to the setting, and the characteristic curve of the motor from no load to locked rotor (or set value) is scanned;

(4) The system has a fixed-point test method: after the motor runs, the load is automatically adjusted to the set value, and it runs stably at the set value;

(5) Test result: The motor test data is displayed in the form of report or curve, which can be printed and saved, which is convenient for opening and querying the curve next time. The curve coordinate parameters (abscissa and ordinate) can be modified

(6) Rated torque test accuracy: ±0.5%; speed accuracy ±0.2%;

(7) Dynamometer range: 0.05Nm-50000Nm (customers can choose a dynamometer with a suitable range according to their motor power)