Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89**
Payment & Shipping Terms
Minimum Order Quantity: 1 Set
Price: Negotiation
Packaging Details: Wooden case
Delivery Time: 45 working days
Supply Ability: 300 sets per month
Product Name: |
Stator Tester |
Color: |
Primary Aluminum |
Height: |
1405mm |
Width: |
660mm |
Depth: |
840mm |
Remote Control: |
Yes |
Product Name: |
Stator Tester |
Color: |
Primary Aluminum |
Height: |
1405mm |
Width: |
660mm |
Depth: |
840mm |
Remote Control: |
Yes |
High Integrated Stator Testing System Of Air Conditioner Indoor Motor
1. Test object: stator of air conditioner motor
2. Test items
Insulation resistance, surge, winding resistance, AC Hipot, direction of rotation
3. Function description
3.1 Built in industrial computer(IPC), Linux operating system, professional software, clear interface
3.2 Standard equipped with yellow, green and red indicating light.
3.3 Test the environment temperature in real time during the DC winding resistance test. And the
resistance testing result will convert to the standard temperature value automatically.
3.4 The left station and right station works alternatively.
3.5 The operators can select test items as required.
3.6 Available selected motor model ≥1000.
3.7 The parameters range for each type of motor can be entered and saved. The inductance and
resistance test has the function of setting and displaying the unbalanced degree.
3.8 Two options are available if the stator fails the test: “continue to test” and “stop the test”. If the stator
fails the ending resistance test, the test will be stopped until testing all the other items.
3.9 The testing data can be saved in the database, including the specific test result for each tested stator.
3.10 The testing data can be exported in the format of Excel via USB interface.
4. Technical specification
Test Item | insulation resistance, surge, winding resistance AC Hipot, and rotation | |
Test station | Dual station, standard equipped with test bench | |
Display | Keyboard + touch screen(10.4 ’) | |
AC Hipot | ||
Output voltage setting range/ precision | AC 500~3000V ±(2%×setting value+10V) | |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×display value+0.05mA) | |
Hipot breakdown current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA | |
Hipot current/resolution | ±(2%×display value+0.05 mA);0.01 mA | |
test time range/resolution | 0.5~999.9s 0.1s/step | |
Insulation resistance | ||
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) | |
insulation resistance testing range/precision | 1~500MΩ ≤100MΩ:±(3%×display value+0.5MΩ); >100MΩ:±(5%×display value+5MΩ) | |
insulation resistance alarm setting range | Max:0~500MΩ;Min:1~500MΩ | |
test time range/resolution | 0.5~999.9s 0.1s/step | |
Surge | ||
output voltage setting range/precision | 500~3000V ±(3%×display value+8V) | |
sampling frequency | 100MHz | |
Surge graph comparison | Area, area difference, corona, phase. Three surge graphs will be displayed on the test interface | |
DC winding resistance | ||
measuring range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set | |
test time range/resolution | 0.5~999s 0.1s/step | |
temperature compensation | Yes | |
temperature probe/measuring range | DS18b20 -10.0℃~+50.0℃ | |
test precision | ±0.5℃(range:-10℃~+50℃) | |
Direction of rotation | ||
rotation | CW/CCW/still |
5. Configuration list
No. | Name | Function | Unit | Quantity |
1 | Master unit | Control the test module and switch the test items, save testing data | Set | 1 |
2 | Test software | Save the test conditions/results, switch the test process | Set | 1 |
3 | Channel switch unit | Switch the let/right station | Set | 1 |
4 | Cabinet and power supply | Integrated driving module | Set | 1 |
5 | Test bench | Integrated customized test bench | Set | 1 |
6. Reference Picture