Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 45 work days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Service: |
24 Hour Quick Response |
Warranty: |
12 Months |
MES Connection: |
Yes |
Data: |
Testing Data Can Be Exported In Excel Form |
OS: |
Windows XP |
Product Name: |
Motor Tester/ BLDC Motor Testing System For Fan |
Service: |
24 Hour Quick Response |
Warranty: |
12 Months |
MES Connection: |
Yes |
Data: |
Testing Data Can Be Exported In Excel Form |
OS: |
Windows XP |
Product Name: |
Motor Tester/ BLDC Motor Testing System For Fan |
Brushless Motor Tester/ BLDC Motor Testing System for Fan
1. Tested object: BLDC motor for fan
2. Product specification: BLDC motor testing system is suit for testing various motors used in home appliances such as air conditioner, fan, air blower, air purifier. There are two types of BLDC motor distinguished by the position of driver, one is internal driver motor, the other one is external driver motor. Test items are different depend on the motor type.
3. Technical parameters:
AC Hipot |
|
Output voltage setting range/ precision |
AC 200~3000V ±(2%×setting value+10V) |
Breakdown current testing range/ precision |
0.10~20.00mA ±(2%×display value+0.05mA) |
Breakdown current presetting alarm range |
Max:0.10~20.00mA;Min:0.00~20.00mA |
Test time range/ resolution |
0.5~999.9s 0.1s/step |
Insulation resistance |
|
Output voltage setting range / precision |
DC 500V/1000V ±(2%× setting value +10V) |
Insulation resistance testing range/ precision |
1~500MΩ ≤100MΩ:±(3%×display value +0.5MΩ); >100MΩ:±(5%× display value+5MΩ) |
Insulation resistance alarm setting range |
Max:0~500MΩ;Min:1~500MΩ |
Test time range/ resolution |
0.5~999.9s 0.1s/ step |
Output voltage setting range / precision |
DC 500V/1000V ±(2%× setting value +10V) |
Surge |
|
Output voltage setting range/precision |
500~3000V ±(3%*display value + 8V) |
Frequency |
100MHz |
Comparison of graph |
Area, area difference, corona, phase, 3 waveforms displayed in the interface |
DC winding resistance |
|
Measuring range/precision |
5.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set |
Test time range/resolution |
0.5~999s 0.1s/step |
Temperature compensation |
Yes |
Temperature probe/ test range |
DS18b20 -10.0℃~+50.0℃ |
Inductance |
|
Frequency |
100Hz/120Hz/1kHz/10kHz |
Test electric level |
0.3V/0.6V/1V |
Test range |
1uH-2H |
Precision |
0.50% |
Performance test(no-load/on-load) |
|
Voltage measuring range/precision |
Vm: DC 20.0~350V ±(3%*setting value +1 word) |
Current measuring range/precision |
Im: 0.010~2.000A ±(0.5%*display value + 2 words) |
Power measuring range/precision |
10.0~700.0W |
RPM measuring range |
Read the FG feedback signal, and calculate as to the output signal (within 3000rpm) |
On load setting range |
0.20 ~0.75Nm |
Rotation test |
CW/CCW/Still |
Phase sequence |
|
Phase sequence |
A-B-C A-C-B B-C-A B-A-C C-A-B C-B-A |
Back EMF |
|
Voltage measuring range/precision |
20~200V ±(0.5%*displayed value +0.5V) |
Speed setting range |
200~3000rpm 1000rpm is recommended. |
FG/Hall |
|
Vcc power supply |
3.00~18.00V ±(0.5%*setting value + 3 words) |
PG/Hall graph |
Waveform display |
Frequency range/precision |
20Hz~1KHz ±(0.5%*display value + 3 words) |
High/low level range/precision |
0.00~18.00V ±(0.5%*display value + 3 words) |
Duty cycle |
0.0~100.0% ±(0.5%*displayed value + 2 words) |
4. Type of tested object: internal driver BLDC motor, external driver BLDC motor (build-in Hall board or position sensor)
5. Test items:
5.1 Internal driver BLDC motor:
Safety: AC Hipot, insulation resistance.
Low voltage start: adjusting voltage of Vsp or Vm to test the performance of motor.
No-loading (optional): no-loading current, no-load power, no-load speed, rotation, FG testing.
On-loading: On-load current, on-load power, on-load speed, rotation.
5.2 External driver BLDC motor:
Safety: AC Hipot, insulation resistance, impulse, DC winding resistance, (testing of motor stator)
Back EMF: EMF voltage, phase, phase difference between back EMF and Hall, (not including motor without Hall inside)
Hall: high electrical level, low electrical level, duty cycle, frequency.
On-load performance: on-load current, on-load power, on-load speed, rotation.
On-load torque/speed is subject to standard sample, OK/NG tolerance can be set.