Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Wooden case
Delivery Time: 45 working days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Product: |
Electric Motor Testing Machine For Milling Machine |
Test Bench Design: |
V-shape Base |
Height: |
1502mm |
Test Station: |
Two Stations |
Testing Data: |
Saved Or Exported |
MES Connection: |
Yes |
Product: |
Electric Motor Testing Machine For Milling Machine |
Test Bench Design: |
V-shape Base |
Height: |
1502mm |
Test Station: |
Two Stations |
Testing Data: |
Saved Or Exported |
MES Connection: |
Yes |
Electric Motor Testing Machine For Milling Machine, Automatic Motor Test
1. Test product: motor of milling machine, powder milling machine.
2. Application industry: home appliance tools
3. Test: surge, winding resistance, insulation resistance, Hipot, Low-voltage start, no-load power
4. Technical parameters:
4.1 Surge
output voltage setting range/precision | 500~3000V ±(3%×setting value+8V) |
sampling frequency | 100MHz |
waveform comparison | area, area difference, corona and phase 3 waveforms displayed in the testing interface |
4.2 DC Winding resistance :
testing range and precision | 10.0mΩ~2KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
test time range/resolution |
0.5~20s 0.1s/step
|
temperature compensation function | Yes |
temperature probe/range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
4.3 Insulation Resistance:
output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) |
insulation resistance testing range/precision |
1~500MΩ ≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ) |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~100MΩ |
test time range/resolution | 0.5~999s 0.1s/step |
4.4 AC Hipot:
Output voltage setting range and precision | AC 500~3000V ±(2%×setting value+10V) |
breakdown current testing range/precision | 0.10~20.00mA ±(2%×setting value+0.05 mA) |
Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
Hipot current/resolution | ±(2% display value+0.05 mA);0.01 mA |
test time range/resolution | 0.5~999.9s 0.1s/step |
Arc detection | 0~9 level |
4.5 Low voltage start:
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
4.6 No-load:
voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) |
current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) |
power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) |
5. Configuration
No. | Name | Specification | Unit |
1 | Master unit | Customized | Set |
2 | Test bench | Customized clamps | Set |
3 | Test software | Save the test requirements, data and control the test process | Set |
4 | Cabinet | Easy to be moved with foot wheels | Set |