Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 45 work days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Product Category: |
Safety Testing System |
Warranty: |
12 Months |
OS: |
Windows XP |
Color: |
Grey (customized) |
Power Supply: |
Customized As The National Grid |
Monitor: |
5.7” LCD Blue Background |
Product Category: |
Safety Testing System |
Warranty: |
12 Months |
OS: |
Windows XP |
Color: |
Grey (customized) |
Power Supply: |
Customized As The National Grid |
Monitor: |
5.7” LCD Blue Background |
Safety Testing System / Refrigerator, Air Conditioner, Washing Machine, Safety Test
1. Test object: air conditioner, refrigerator, washing machine, microwave oven.
2. Safety testing system introduction:
The safety testing system supports to test both the safety and power, providing 2-channel test power input and solve the problem of power switch caused by the voltage inconsistency of leakage current test and power test. Optional equipped with the USB port for testing data save and export.
3. Technical specification
Grounding resistance |
|
Grounding current output range/ precision |
AC 5.0~30.0A ±(3%×display value+5words) |
Grounding resistance alarm setting range |
Max:5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ; Min:0.0~100mΩ |
Grounding resistance test range/precision |
10.0~600mΩ ±(3%×display value +5 words) |
Test time range / resolution |
1~60s 1s/step |
AC Hipot |
|
Output voltage setting range/ precision |
AC 200~5000V ±(3%×setting value+5 words) |
Breakdown current test range / precision |
0.10~25.00mA ±(3%×display value +5 words) |
Breakdown current presetting alarm range |
Max:0.10~25.00mA ;Min:0.00~5.00mA |
Test time range / resolution |
1~300s 1s/step
|
Leakage current |
|
Output voltage |
1.06 times rated voltage |
Leakage type setting |
Dynamic leakage, static leakage, optional equipped with 3 types of body network, which can be customized and switched freely. |
Output voltage test range/ precision |
AC 50~280V ±(0.5%×display value +2 words) |
Leakage current setting alarm range |
Max:0.05~20.00mA;Min:0.01~5.00mA |
Leakage current test range/ precision |
0.05~20.00mA ±(1.5%×display value +0.02mA) |
Test time range |
1~300s 1s/step |
Insulation resistance |
|
Output voltage setting range/ precision |
DC 500/1000V ±(3%×reading +5 words) |
Insulation resistance test range / precision |
1~2000MΩ ≤100MΩ:±(5%×display value +3 words) >100 MΩ:±(8%×display value +8 words) |
Insulation resistance alarm setting range |
Max:0~2000MΩ;Min:1~2000MΩ |
Test time range / resolution |
1~300s 1s/step |
4. Features
4.1 Hipot voltage is featured with ramp up/down setting, maximum and minimum value alarm.
4.2 Digital closed-loop feedback control mode, automatic voltage adjustment mode, output voltage/current automatic correction avoid the influence of grid fluctuation, all of these ensure the test precision.
4.3 Voltage and resistance judging mode are available for the grounding resistance test, which meet the requirements of different national/industrial standards.
4.4 5.7” LCD monitor with blue background, and the data display is clear.
4.5 15 groups of test programs can be saved and each program name can be set and searched by the name.
4.6 Fast -speed: safety testing system equipped with ARM high speed processor, which process data comprehensively and fast.
4.7 Flexibility: wide application range, test items are flexible to be selected.
5. Safety testing system reference picture