Product Details
Place of Origin: China
Brand Name: AIP
Model Number: AIP89XX
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 45 work days
Payment Terms: L/C, T/T
Supply Ability: 50 sets per month
Product Category: |
Safety Testing System |
Data: |
Testing Data Can Be Exported In Excel Form |
Power Supply: |
Customized As The National Grid |
Color: |
Grey (customized) |
Service: |
Support Remote Control Failure Diagnose |
Product Name: |
Electrical Safety Testing System For Fan |
Product Category: |
Safety Testing System |
Data: |
Testing Data Can Be Exported In Excel Form |
Power Supply: |
Customized As The National Grid |
Color: |
Grey (customized) |
Service: |
Support Remote Control Failure Diagnose |
Product Name: |
Electrical Safety Testing System For Fan |
Safety Testing System / Electrical Safety Testing System for Fan
1. Features:
2. Technical parameters:
AC Hipot |
|
Output voltage setting range/precision |
AC 200~5000V ±(3%*setting value + 5 digit) |
Breakdown current measuring range/precision |
0.10~99.99mA ±(3%*displayed value + 5 digit) |
Presetting breakdown current alarm range/precision |
Up limit: 0.10~99.99mA; Lower limit: 0.00~5.00mA |
Testing time range/resolution |
1~300S 1s/step |
Insulation resistance |
|
Output voltage setting range/precision |
DC 500/1000V ±(3%*displayed value + 5 digit) |
Insulation resistance measuring range/precision |
1~2000MΩ Within 100MΩ: ±(5%*displayed value + 3 digit); Above 100MΩ: ±(8%*displayed value + 8 digit); |
Presetting insulation resistance alarm range/precision |
Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ |
Testing time range/resolution |
1-300s 1s/step |
Grounding |
|
Ground current output range/precision |
AC 5.0~30.0A ±(3%*setting value + 5 digit) |
Ground resistance measuring range/precision |
10.0~600mΩ±(3%*displayed value + 5 digit) |
Presetting ground resistance alarm range |
Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ Lower limit: 0.0 ~100mΩ |
Testing time/resolution |
1~60s 1s/step |
Leakage current |
|
Output voltage |
1.06 times of nominal voltage |
Output voltage measuring range/precision |
AC 50~280V ±(0.5%*displayed value + 2 digit) |
Leakage current measuring range/precision |
0.05~20.00mA ±(3%*displayed value +0.02mA) |
Presetting leakage current alarm range |
Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA |
Testing time range/resolution |
1~300s 1s/step |
power |
|
Output voltage |
Equals input voltage |
Output voltage measuring range/precision |
AC 50~280V ±(0.5%*displayed value + 2 digit) |
Output current measuring range/precision |
AC 0.20~30.00A ±(0.5%*displayed value + 2 digit) |
Power measuring range/precision |
30~6000W ±(0.5%*displayed value + 5 digit) |
Presetting power alarm range |
Up limit: 30~6000W; Lower limit: 0~6000W |
Testing time/resolution |
1~300s 1s/step |
Low voltage starts |
|
Output voltage |
O.85 times of input voltage |
Output voltage measuring range/precision |
AC 50~280V ±(0.5%*displayed value + 2 digit) |
Starting current measuring range/precision |
AC 0.20~30.00A ±(0.5%*displayed value + 2 digit) |
Presetting current alarm range |
Up limit: 0.20~30.00A; Lower limit: 0.00~25.00A |
Testing time/resolution |
1~300s 1s/step |
3. About electrical safety testing:
4. Image of tested object:
5. Image of electrical safety testing system